Power Source | Usable power supply unit: VX-200PS 24 V DC (operational range: 20 V - 40 V DC) Two power inputs construction enables dual-redundant power supply. |
---|---|
Current Consumption | 0.34 A or less (maximum value in the power operating range) 0.29 A or less (when operated on 24 V DC) |
Indication | Control input indicator (32), Power indicator, CPU OFF indicator, FAULT indicator |
Control Output | 32 outputs, no-voltage make contact output, relay contact output (withstand voltage: 40 V DC, control current: 2 mA to 300 mA), removable terminal block (6 pins) |
Input/Output Connector | Input: 1 input, Output: 1 output RJ45 Connector |
---|---|
Connection Cable | Shielded Category 5 twisted pair cable (CAT5-STP) (1 pair of data wire + 1 pair of control wire) |
Maximum Cable Distance | 800 m (874.89 yd) |
Operating Temperature | 0 ℃ to +40 ℃ (32 ゜F to 104 ゜F) |
---|---|
Operating Humidity | 35 % to 80 %RH (no condensation) |
Finish | Panel: Aluminum, black, alumite Case: Surface-treated steel plate |
Dimensions | 482 (W) × 44 (H) × 331.5 (D) mm (18.98 × 1.73" × 13.05")" |
Weight | 3.6 kg (7.94 lb) |
Accessory | Removable terminal plug (6 pins) …16, Removable terminal plug (4 pins) …1, Rack mounting screw …4 |
When operating in matrix mode
Power Source | Usable power supply unit: AD-011, AD-031B 24 V DC (operational range: 20 V - 40 V DC) Two power inputs construction enables dual-redundant power supply. |
---|---|
Current Consumption | 0.34 A or less (maximum value in the power operating range) 0.29 A or less (when operated on 24 V DC) |
Indication | Control input indicator (32), Power indicator, CPU OFF indicator, FAULT indicator |
Control Output | 32 outputs, no-voltage make contact output, relay contact output (withstand voltage: 40 V DC, control current: 2 mA to 300 mA), removable terminal block (6 pins) |
Input/Output Connector | Input: 1 input, Output: 1 output RJ45 Connector |
---|---|
Connection Cable | Shielded Category 5 twisted pair cable (CAT5-STP) (1 pair of data wire + 1 pair of control wire) |
Maximum Cable Distance | 800 m (874.89 yd) |
Operating Temperature | 0 ℃ to +40 ℃ (32 ゜F to 104 ゜F) |
---|---|
Operating Humidity | 35 % to 80 %RH (no condensation) |
Finish | Panel: Aluminum, black, alumite Case: Surface-treated steel plate |
Dimensions | 482 (W) × 44 (H) × 331.5 (D) mm (18.98 × 1.73" × 13.05")" |
Weight | 3.6 kg (7.94 lb) |
Accessory | Removable terminal plug (6 pins) …16, Removable terminal plug (4 pins) …1, Removable terminal plug (2 pins) ...1, Rack mounting screw …4 |
When operating in stand-alone mode
Power Source | Usable power supply unit: AD-011, AD-031B 24 V DC (operational range: 20 V - 40 V DC) Two power inputs construction enables dual-redundant power supply. |
---|---|
Current Consumption | 0.34 A or less (maximum value in the power operating range) 0.29 A or less (when operated on 24 V DC) |
Indication | Control input indicator (32), Power indicator, CPU OFF indicator, FAULT indicator |
Control Output | 32 outputs, no-voltage make contact output, relay contact output (withstand voltage: 40 V DC, control current: 2 mA to 300 mA), removable terminal block (6 pins) |
Connection Cable | Main Cable: Shielded CPEV cable* or STP Category 5 straight cable *when connecting the power supply to each unit: 1 pair for data line when connecting the power supply only to the SX-2000CI: 1 pair data line and 2 pairs power line for a redundant power supply system, or 1 pair data line and 1 pair power line for a non-redundant power supply system Brach cable: STP Category 5 straight cable (with RJ45 connectors) |
Maximum Cable Distance | 800 m (874.89 yd) |
Maximum Delay Time | 300 ms |
Operating Temperature | 0 ℃ to +40 ℃ (32 ゜F to 104 ゜F) |
---|---|
Operating Humidity | 35 % to 80 %RH (no condensation) |
Finish | Panel: Aluminum, black, alumite Case: Surface-treated steel plate |
Dimensions | 482 (W) × 44 (H) × 331.5 (D) mm (18.98 × 1.73" × 13.05")" |
Weight | 3.6 kg (7.94 lb) |
Accessory | Removable terminal plug (16 pins) …4, Removable terminal plug (4 pins) …1, Removable terminal plug (2 pins) …1, Rack mounting screw …4 |
Option | DC Power Supply Panel: AD-011, AD-031B Terminal Unit: RM-200RJ |